egg incubator 1. suitable for the families and specialized households 2. incubate chickens, ducks and geese, etc

egg incubator

Indicating lamp state instruction:

WORK lamp on the left side of display screen is made as work indicating lamp, LED normally on means it’s in heating state.

SET lamp on the left side of display screen is used for indicating lamp set, LED normally on means it’s in setting state.

Function instruction:

HU, HD:

Parameter HU and HD, set by factory, is supposed not to be modified by user.

Temperature correction function: 

When measuring temperature deviates from reference temperature, temperature correction function shall be used to make the measuring value in accordance with reference temperature, temperature after correction shall be the sum of temperature before correction and correction value (correction value can be positive number, negative number or zero).

Temperature correction set:

Push “SET” for 3s to enter menu display, push “+” or  “-” until code “CA” appears on screen, then push “SET” to display temperature correction setting value, push “+” or “-” again to adjust parameter.

Upper and lower limit function:

HS and LS set limits setting range of temperature control, e.g., if HS is set as +15 and LS is set as -10, then the temperature can only be set from -10 to +15, so the display value still keeps as -10 after pushing  “-” if it displays -10; the display value still keeps as +15 after pushing ““+”” if it displays +15. If setting value is beyond the setting range, then HS and LS must be changed at first.

  Upper and lower limit set:

Push “SET” for 3s to enter menu display, push “+” or  “-” until code “HS” or “LS” appears on screen, push “SET” to display upper or lower limit setting value, then push “+” or “-” to adjust the parameter. HS means upper limit and LS means lower limit.

Humidity alarm function:

If measuring humidity is less than AU setting value, the temperature controller sends alarm and the humidity indicating lamp flickers. The alarm can stop by pushing any button.

Humidity alarm set:

Push “SET” for 3s to enter menu display, push “+” or  “-” until code “AS” appears on screen, push “SET” to display humidity alarm setting value, then push “+” or  “-” again to adjust parameter.

High temperature alarm function:

If measuring temperature is higher than sum of setting temperature and AH, the temperature controller sends alarm and the display screen alternately displays H and current temperature. The alarm can stop by pushing any button.

 

 

High temperature alarm set:

Push “SET” for 3s to enter menu display, push “+” or  “-” until code “AH” appears on screen, push “SET” to display high temperature alarm setting value, then push “+” or “-” to adjust parameter, the high temperature alarm function can be closed when AH is set as 0.

Low temperature alarm function:

If measuring temperature is lower than the result when setting temperature minus AL, the temperature controller sends alarm and the display screen alternately displays L and current temperature. The alarm can stop by pushing any button.

Operation Instruction, Safety Notice

1. Only the power supply marked on the incubator can be used;

2. Don’t put any goods on the wire, the power line of incubator shall be placed where it won’t be stepped on or make people trip and fall;

3. Make sure that the socket and extension line in use don’t overload, otherwise, it may cause fire or electric shock;

4. If the incubator is smoking, or sending abnormal smell or unusual noise, please cut off the power supply and pull down the power line to stop the fault, after that, contact the agency or maintenance center;

5. Don’t touch the power line with wet hand, or it may cause electric shock;

6. This incubator can’t be exposed to rain and sunshine;

7. Make sure that the power supply is switched off before cleaning the incubator;

8. The incubator shall be placed in room where has good air but no vibratory equipment, it can’t be placed in room with fast air movement or room with harmful and noxious chemicals and other pollutants.

9. Don’t block the air-bleed hole when the incubator is in work condition.